Combustible materials may be installed ush with the front of the appliance but must not cover any of the black
face-areas of the appliance. Non-combustible material (brick, stone or ceramic tile) may protrude in these
areas.
It is not necessary to install a hearth extension with this appliance.
When roughing in the appliance, raise the appliance to accommodate for the thickness of the nished oor ma-
terials, i.e. tile, carpeting, hard wood, which if not planned for will interfere with the opening of the lower access
door and the installation of many decorative ashing accessories.
Objects placed in front of the appliance should be kept a minimum of 48" away from the glass front faces.
Refer to "FINISHING" section for complete instructions
regarding mantel requirements and installations, log place-
ment, glass door and upper and lower louvre attachments.
A minimum of 3" of cement board or non-combustible
equivalent must be installed against the side edge of the
appliance.
!
WARNING
FINISHING MUST BE DONE USING A NON-COMBUSTIBLE MATERIAL PLACED FLUSH WITH THE
FRONT FACE OF THE APPLIANCE AND EXTENDING FROM THE TOP OF THE APPLIANCE SUCH AS
CEMENT BOARD, CERAMIC TILE, MARBLE, ETC. WHEN FINISHING TO THE APPLIANCE. DO NOT
USE WOOD OR DRYWALL. ANY FIRE RATED DRYWALL IS NOT ACCEPTABLE.
DRYWALL
5"
MIN
DRYWALL
3"
NON-
COMBUSTIBLE
Install the base panels as illustrated in steps 1-4, see "PENINSULA
INSTALLATION PROCEDURE" section. The side panel sits under the
bracket tab. Holding the side panel in position, bend down the tab to
secure. DETAIL 6.
STEP 5
STEP 6
RETAINER
DETAIL 6
5.3 BRICK PANEL INSTALLATION
5.4 FACING
5.5 FINISHING