3.8 HORIZONTAL TERMINATION
16.5
Simple venting con guration (only one 45° and 90°
elbow)
(H
T
) < (V
T
)
For vent con gurations requiring more than one 45° elbow and 90° elbow, the following formulas
apply:
Formula 1: H
T
< V
T
Formula 2: H
T
+ V
T
< 40 feet
Example:
V
1
= 8 FT
V
T
= V
1
= 8 FT
H
1
= 2.5 FT
H
2
= 2 FT
H
R
= H
1
+ H
2
= 2.5 + 2 = 4.5 FT
H
O
= .03 (one 45° elbow + two 90° elbows - 135°) = .03 (225 - 135°) = 2.7 FT
H
T
= H
R
+ H
O
= 4.5 + 2.7 = 7.2 FT
H
T
+ V
T
= 7.2 + 8 = 15.2 FT
Formula 1: H
T
< V
T
7.2 < 8
Formula 2: H
T
+ V
T
< 40 FT
15.2 < 40
Since both formulas are met, this vent con guration is acceptable.
90°
90°
45°
V
1
H
1
H
2
0
2.5 5 7.5 10 12.5 15
40
10
20
30
17.5 20
39
REQUIRED
VERTICAL
RISE IN
FEET V
T
HORIZONTAL VENT RUN PLUS OFFSET IN
FEET H
T
See graph to determine the required vertical
rise V
T
for the required horizontal run H
T
.
The shaded area within the lines represents
acceptable values for H
T
and V
T
Page view 13