INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE.
INSTALLATION AND
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
Phone (705)721-1212 • Fax (705)722-6031 • www.continental replaces.com • ask@continental re.on.ca
1.24B
$10.00
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.
SAFETY INFORMATION
!
WARNING
- Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbours phone. Follow the gas suppliers
instructions.
If you cannot reach your gas supplier, call the
re department.
- Installation and service must be performed by a
quali ed installer, service agency or the supplier.
If the information in these instructions
are not followed exactly, a re or
explosion may result causing property
damage, personal injury or loss of life.
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
!
WARNING
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certi ed kit is used.
BCDV42CFN
NATURAL GAS
BCDV42CFP
PROPANE
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.22, ANSI Z21.50 FOR VENTED GAS FIREPLACES.
Page view 0
1 2 3 4 5 6 ... 47 48

Summary of Contents

Page 1 - BCDV42CFP

1W415-0780 / D / 08.13.12INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.NEVER LEAVE CHILDREN OR O

Page 2 - TABLE OF CONTENTS

10W415-0780 / D / 08.13.123.3 SPECIAL VENT INSTALLATIONS3.3.1 PERISCOPE TERMINATIONUse the periscope kit to locate the air termination above grade. T

Page 3 - 1.0 INSTALLATION OVERVIEW

11W415-0780 / D / 08.13.123.4 VENT TERMINAL CLEARANCESINSTALLATIONSCANADA U.S.A.A 12” 12” Clearance above grade, veranda porch, deck or balcony.B 12”

Page 4 - 2.0 INTRODUCTION

12W415-0780 / D / 08.13.123.5 VENT APPLICATION FLOW CHART13.1TOP EXITHorizontal TerminationVertical TerminationVertical rise is equal to or greater t

Page 5 - 2.1 DIMENSIONS

13W415-0780 / D / 08.13.123.8 HORIZONTAL TERMINATION16.5Simple venting confi guration (only one 45° and 90° elbow)(HT) < (VT)For vent confi gurations

Page 6 - 2.3 GENERAL INFORMATION

14W415-0780 / D / 08.13.1216.5_2Simple venting confi guration (only one 45° and 90° elbow)(HT) > (VT)For vent confi gurations requiring more than one

Page 7 - 3.0 VENTING

15W415-0780 / D / 08.13.123.9 VERTICAL TERMINATION(HT) < (VT) Simple venting configurations.See graph to determine the required vertical rise VT fo

Page 8

16W415-0780 / D / 08.13.12(HT) > (VT) Simple venting configurations.See graph to determine the required vertical rise VT for the required horizonta

Page 9

17W415-0780 / D / 08.13.124.0 INSTALLATION4.1 WALL AND CEILING PROTECTION!WARNINGFOR SAFE AND PROPER OPERATION OF THE APPLIANCE, FOLLOW THE VENTING I

Page 10 - 3.3.1 PERISCOPE TERMINATION

18W415-0780 / D / 08.13.124.2 HORIZONTAL INSTALLATIONThis application occurs when venting through an exterior wall. Having determined the correct heig

Page 11 - 3.4 VENT TERMINAL CLEARANCES

19W415-0780 / D / 08.13.124.3 VERTICAL INSTALLATIONThis application occurs when venting through a roof. Installation kits for various roof pitches are

Page 12 - -135° when combined

2W415-0780 / D / 08.13.12NOTE: Changes, other than editorial, are denoted by a vertical line in the margin.TABLE OF CONTENTS1.0 INSTALLATION OVERVIEW

Page 13 - 3.8 HORIZONTAL TERMINATION

20W415-0780 / D / 08.13.124.4.1 HORIZONTAL AIR TERMINAL INSTALLATIONA. Stretch the inner fl ex pipe to the required length taking into account the add

Page 14 - ) > (V

21W415-0780 / D / 08.13.124.4.2 VERTICAL AIR TERMINAL INSTALLATIONA. Fasten the roof support to the roof using the screws provided. The roof support

Page 15 - ) < (V

22W415-0780 / D / 08.13.127.6This appliance is designed to be attached to a 3” co-linear aluminum fl ex vent system running the full length of a masonr

Page 16

23W415-0780 / D / 08.13.12This appliance is also certifi ed to be installed as an OEM (Original Equipment Manufacturer) installation in a manufactured

Page 17 - 4.0 INSTALLATION

24W415-0780 / D / 08.13.12For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenient location

Page 18 - 4.2 HORIZONTAL INSTALLATION

25W415-0780 / D / 08.13.1225 1/4”1 1/2”MAX41 3/4”46 1/2”14” MIN1 1/2” MAX49” MINIMUM ENCLOSURE HEIGHTNOTE: Do not build into this area - it must be le

Page 19 - 4.3 VERTICAL INSTALLATION

26W415-0780 / D / 08.13.12Minimum clearance to combustible construction from appliance and vent surfaces:Combustible framing:Sides, back, bottom and t

Page 20 - PIPE

27W415-0780 / D / 08.13.125.3 MINIMUM ENCLOSURE CLEARANCESThe appliance requires a minimum enclosure height of 49“. For temperature requirements, the

Page 21 - ROOF SUPPORT

28W415-0780 / D / 08.13.126 1/2"MINUSE ONLY NON-COMBUSTIBLE MATERIAL SUCH AS CEMENT BOARD, CERAMIC TILE, MARBLE, ETC. WHEN FINISHING TO THE FIREP

Page 22

29W415-0780 / D / 08.13.125.5 MINIMUM MANTEL CLEARANCES!WARNINGRISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE TO

Page 23 - 4.7 GAS INSTALLATION

3W415-0780 / D / 08.13.121.0 INSTALLATION OVERVIEWSee the section “MINIMUM MANTEL AND ENCLOSURE CLEARANCES”Side WallSee the section “INSTALLATION-FRAM

Page 24 - 5.0 FRAMING

30W415-0780 / D / 08.13.12The valve access door rotates on the pins attached to the side frame. Lift the valve ac-cess door off the pins to operate th

Page 25

31W415-0780 / D / 08.13.12The grate for this appliance has been removed for shipping purposes.The grate must be installed before the logs are installe

Page 26 - 45"

32W415-0780 / D / 08.13.12C. Place the bottom of the left crossover log (#4) onto the stud on the left side of the log support. The top of the log sh

Page 27 - 5.2 INSTALLING STANDOFFS

33W415-0780 / D / 08.13.127.0 OPTIONAL BLOWER INSTALLATION7.1 ACCESSING THE BLOWERA. Remove the main door, see "DOOR INSTALLATION / REMOVAL&quo

Page 28 - 5.4 ALCOVE FRAMING

34W415-0780 / D / 08.13.12INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER and must be electrically connected and grounded in accordance with local co

Page 29

35W415-0780 / D / 08.13.128.0 OPERATIONEnsure that a continuous gas flow is at the burner before installing the door. When lit for the first time, the

Page 30 - 6.0 FINISHING

36W415-0780 / D / 08.13.129.0 ADJUSTMENTS9.1 PILOT BURNER ADJUSTMENTAdjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direc

Page 31 - 6.5 LOG PLACEMENT

37W415-0780 / D / 08.13.129.3 FLAME CHARACTERISTICSIt’s important to periodically perform a visual check of the pilot and burner fl ames. Compare them

Page 32 - 6.10 LOGO PLACEMENT

38W415-0780 / D / 08.13.125.1DO NOT CLEAN GLASS WHEN HOT! DO NOT USE ABRASIVE CLEANERS TO CLEAN GLASS. Buff lightly with a clean dry soft cloth. Clean

Page 33 - 7.1 ACCESSING THE BLOWER

39W415-0780 / D / 08.13.1210.2 GLASS / DOOR REPLACEMENTA. Place the door frame face down careful not to scratch the paint.B. Center the gasketed gl

Page 34 - 7.2 INSTALLING THE BLOWER

4W415-0780 / D / 08.13.122.0 INTRODUCTION3.1C!WARNING• THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED.• ANY CHANGES TO

Page 35 - 8.0 OPERATION

40W415-0780 / D / 08.13.1211.0 REPLACEMENTSContact your dealer or the factory for questions concerning prices and policies on replacement parts. Norma

Page 36 - 9.0 ADJUSTMENTS

41W415-0780 / D / 08.13.12 ACCESSORIESREF NO. PART NO. DESCRIPTION43* W573-0007 10.3OZ TUBE HIGH TEMP SEALANT44*W660-0081 MILLIVOLT THERMOSTAT45* F40

Page 37 - 9.3 FLAME CHARACTERISTICS

42W415-0780 / D / 08.13.12ACCESSORIESREF NO. PART NO. DESCRIPTION58* W175-0166 5" COUPLER59* W175-0002 8" COUPLER60*W500-0206 TERMINAL EXT

Page 38 - MAINTENANCE

43W415-0780 / D / 08.13.1212.0 TROUBLESHOOTINGSYMPTOM PROBLEM TEST SOLUTIONMain burner goes out; pilot stays on.Pilot fl ame is not large enough or not

Page 39

44W415-0780 / D / 08.13.12SYMPTOM PROBLEM TEST SOLUTIONPilot will not light. No spark at pilot burner. - Check if pilot can be lit by a match. - Chec

Page 40 - 11.0 REPLACEMENTS

45W415-0780 / D / 08.13.1242.3_3SYMPTOM PROBLEM TEST SOLUTIONWhite / grey fi lm forms. Sulphur from fuel is being deposited on glass, logs or combustio

Page 41 - ROOM TERMINAL KITS

46W415-0780 / D / 08.13.1213.0 WARRANTYCONTINENTAL® warrants its products against manufacturing defects to the original purchaser only. Registering yo

Page 42 - ACCESSORIES

47W415-0780 / D / 08.13.1214.0 SERVICE HISTORY43.1

Page 43 - 12.0 TROUBLESHOOTING

48W415-0780 / D / 08.13.12

Page 44 - SYMPTOM PROBLEM TEST SOLUTION

5W415-0780 / D / 08.13.122.2 GENERAL INSTRUCTIONS3"5 1/2"ELECTRICAL INLETLEFT SIDE41 1/2"37"20 1/2"25"46"23"5&

Page 45

6W415-0780 / D / 08.13.122.3 GENERAL INFORMATION4.1A The installation must conform with local codes or, in absence of local codes, the National Gas an

Page 46 - 13.0 WARRANTY

7W415-0780 / D / 08.13.122.4 RATING PLATE INFORMATIONINSTALLER: It is your responsibility to check off the appropriate box on the rating plate accord

Page 47 - 14.0 SERVICE HISTORY

8W415-0780 / D / 08.13.123.1 VENTING LENGTHS AND COMPONENTSUse only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent or M

Page 48 - W415-0780 / D / 08.13.12

9W415-0780 / D / 08.13.123.2 TYPICAL VENT INSTALLATIONS38 1/2" MIN PLUS RISE*18" MAX40 FT16" MIN* See venting section.NOTE: When termi